AMC16-DETT Multi-Circuit DC Energy Meter Used In Base Sation

 

● DC rated voltage: 1 channel: -48VDC

● Accuracy:1%In≤I≤10%In error±2.5%; I>10%In error±2%

● RS485(MODBUS-RTU)

● DIN 35 mm

● Designed for base stations


description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Characteristic
Product Description
 

   Base station dedicated DC energy meter AMC16-DETT is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering. The meter could measure6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software.have the functions of telemetering, teleindication, teleadjusting, metering at real time,energy quality abnormal alarm, data storage and processing,data interaction.

Parameter
 
Technical parameter Index
Input DC rated voltage 1 channel: -48VDC
DC current 6 channels hall sensors: total 200A/5V, China Telecom, China
Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd
channel reserve 100A/5V
Commercial power 1 channel: 0-5VDC
monitoring
Overload capacity Voltage:1.2times continued,2 times continued 1s;
Current: 1.2 times continued,10 times continued 1s
Accuracy (superposition hall sensors) 1%In≤I≤10%In error±2.5%; I>10%In error±2%
Measurement resolution Voltage output accuracy 0.01V; current output accuracy 0.01A;
power output accuracy 0.01kw; energy output accuracy 0.01kwh
Functions Basic function Monitor device system time, total voltage, output total current, power,
energy, each channel voltage, current, power, energy;
LED indicator display;485 communication.
Metering function Start current: under rated voltage,
when the load current value of the meter doesn’t exceed 1% of the max. current, the meter starts.
Shunt running current: when there is no current in the current
circuit of the meter, and 85%-125%of the rated voltage is applied on the voltage circuit,
the calculator shall not have more than one digital change.
Alarm function DC voltage output low alarm,DC voltage output high alarm,one
power down alarm, module voltage loss alarm, metering branch
error alarm, internal program error alarm, clock error alarm,
memory failure alarm, AC input power failure alarm
Timing function support broadcast timing, could remote timing to the meter
through RS485 communication.
Communication Single channel RS485, baudrate 9600bps, can be set to 1200BPS,
2400bps, 4800bps.
Communication protocol: standard or custmized
Hall sensor power supply Power supply output:+12V/100Ma, -12V/50mA
Clock accuracy ≤0.5S/d(23℃), ≤1S/d(-20℃-60℃),
Auxiliary Voltage range -40V~-60VDC
supply Power consumption Whole device≤2W( no hall power supply output)
Storage It has the storage function of historical power data and historical alarm information,
and the memory is 2MB
Insulation resistance ≥40MΩ
Environment Temperature Working : -20℃~+60℃; storage:-40℃~+70℃
Humidity ≤98% no condensation, no corrosive gas place
Altitude ≤4000m
Protection level IP20
Material flame retardent Terminal glow wire temperature 960℃±10℃ ,shell glow wire
temperature 6500℃±15℃
Installation Standard 35mm din rail
Lightning Voltage input Peak value 5kA
protection (differential mode)
  Auxiliary supply Peak value 5kA
  (differential mode)

Wiring

 
 

① Seal for Anti theft

② Brand

③ Panel

④ Enter-wire

⑤ Auxiliary function

⑥ Pulse output light

⑦ Button

⑧ Outlet wire              

Dimension

 

Network

 
 
 
 
 
 
 

 

 

 

Download
  •  CE CERTIFICATE

 

Related Products

Shop our new arrivals and best sellers. Click on the image to see product details and click Buy to add a product to cart. We are committed to give you the best buying experience!

CONTACT US