AIM-T500L Industrial Insulation Monitoring Device with Fault Locate

 

● LCD display with backlit

● Unearthed AC,DC main circuits

● IT systems including high leakage capacitances

● Coupled IT systems

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Characteristic
Product Description
 

   AIM-T500L series industrial insulation monitoring and fault is specially developed by Acrel for IT distribution system in industrial occasions such as mine, glass factory, electric furnace and test equipment, ship, metallurgical plant, chemical plant, explosion hazard site, computer center and emergency power supply. The system has rich functions, including insulation resistance monitoring, insulation fault warning, insulation fault alarm, event recording, parameter setting, communication networking, etc. When the system has grounding fault, it can give a timely alarm and accurately locate the specific circuit of the fault to remind staff to check the fault in time.  The products conform to the requirements of enterprise standard Q/VDCL-26-2017 IT System Insulation Monitor.

 
Parameter
 

Item

Parameter

Accessory power supply

AC 85~265V; DC100~300V; 50/60Hz

Power dissipation

< 8W

System voltage

AC 0~690V; DC 0~800V; 40~460Hz

System application

IT system (online), Other system (offline)

Insulation monitoring

Measuring range

1k~10MΩ

Alarm range

10k~10MΩ

Resistance accuracy

1~10k,1k; 10k~10M, ±10%

system leakage capacitance

<500μF

Response time (Ce=1μF)

<5s

Internal parameters

Measuring voltage

<50V

Measuring current

<270μA

Internal DC impedance

≥180kΩ

Relay output

Error, Alarm, Warning

SOE

20 records (fault type, fault value, fault time)

Alarm type

LCD, LED indicator

Communication

RS485, Modbus-RTU; CAN, custom

Impulse voltage / Pollution Level

8kV/Ⅲ

EMC/ Radiation

IEC61326-2-4

Environment

Working temperature

-10 ~+65℃

Storage temperature

-20~+70℃

Relative humidity

<95%, without condensation

Altitude

≤2500m

Dimension
 

 

Lcd Display
 
 
Network
 
 
 
 
 
 

Related Products