AHKC-EKB Open-loop Hall Effect Transducer (Split-core)

 

Rated Input: 0~(200-1000A)

Rated Output: 5V/4V

Power Supply: ±12~±15Vdc

Accuracy: Class 1.0

Response Time: ≤5us

Installation: Clamp on (Split-core) measuring cable and screw fixed on panel

Standard&Certificate: CE; IEC; LVD

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Characteristic
Dimension
 

Size / Type

Overall dimensions

Hole size

Installation dimensions

Picture

W

H

D

a

e

Φ

M

N

Picture 1

AHKC-EKA

60

64

16

/

/

20

47

/

Picture 1

AHKC-EKAA

60

64

16

/

/

20

47

/

Picture 1

AHKC-EKDA

60

64

16

/

/

20

47

/

Picture 1

AHKC-EKB

100

102

24

/

/

40

80

/

Picture 1

AHKC-EKBA

100

102

24

/

/

40

80

/

Picture 1

AHKC-EKBDA

100

102

24

/

/

40

80

/

Picture 1

AHKC-EKC

115

110

27

/

/

55

95.5

/

Picture 1

AHKC-EKCA

115

110

27

/

/

55

95.5

/

Picture 1

AHKC-EKCDA

115

110

27

/

/

55

95.5

30

Picture 2

AHKC-K

127

63

25

64

16

/

/

30

Picture 2

AHKC-KAA

127

63

25

64

16

/

/

30

Picture 2

AHKC-KDA

127

63

25

64

16

/

/

46

Picture 2

AHKC-H

149

79

25

82

32

/

/

60

Picture 2

AHKC-KA

176

95.5

29

104

36

/

/

80

Picture 2

AHKC-HB

204

111.5

29

132

52

/

/

48*2

Picture 2

AHKC-HBAA

204

111.5

29

132

52

/

/

48*2

Picture 2

AHKC-HBDA

204

111.5

29

132

52

/

/

48*2

Picture 2

Wiring 
 
Installation
 
When the Hall sensor is in use, in order to obtain better dynamic characteristics and sensitivity, attention must be paid to the coupling between the primary coil and the secondary coil. It is recommended to use a single wire and the wire completely fills the hole of the Hall sensor module;
  •  
  •  
  •  
  •  
Application
 
Parameters

Parameters

Index

Rated Input Current

0~±(50-1000)A

Rated Output Voltage

±5V/±4V

Accuracy Class

1.0

Power Voltage

DC±15V(allowable fluctuation±20%)

Zero Offset Voltage

±20mV

Offset Voltage Drift

≤±1.0mV/℃

Linearity

≤0.2%FS

Response Time

≤5us

Bandwidth

0~20kHz

Isolation Voltage

3.5kV/50Hz/1min

Operating Temperature

-40℃~85℃

Storage Temperature

-40℃~85℃

Consumption

≤0.5W